9.3 Garantie
Der Hersteller gewährt auf das Produkt eine Garantie ab Kaufdatum.
Von der Garantie sind Mängel umfasst, die nachweislich auf Material-,
Fertigungs- oder Konstruktionsfehlern beruhen und innerhalb des Ga­
rantiezeitraums dem Hersteller gegenüber geltend gemacht werden.
Nähere Informationen zu den Garantiebedingungen erteilt die zustän­
dige Vertriebsgesellschaft des Herstellers.
10 Technische Daten
Kennzeichen
Gewicht [g]
Systemhöhe [mm]
Einbauhöhe [mm]
Material
Max. Körpergewicht [kg]
1 Product description
INFORMATION
Date of last update: 2021-06-01
► Please read this document carefully before using the product
and observe the safety notices.
► Instruct the user in the safe use of the product.
► Please contact the manufacturer if you have questions about the
product or in case of problems.
► Report each serious incident related to the product to the manu­
facturer and to the relevant authority in your country. This is par­
ticularly important when there is a decline in the health state.
► Please keep this document for your records.
1.1 Construction and Function
The 4R118 adapter plate is installed between the socket attachment
block and the socket adapter of a TF prosthesis. It shifts the prosthet­
ic knee joint in the posterior direction. The adapter plate can be used
for repositioning between 10 mm and 25 mm.
1.2 Combination possibilities
This prosthetic component is compatible with Ottobock's system of
modular connectors. Functionality with components of other manufac­
turers that have compatible modular connectors has not been tested.
Limited combination options for Ottobock components
This product can be combined with the following Ottobock compon­
ents:
4R118
75
10
10
Aluminium
2 Intended use
125
2.1 Indications for use
The product is intended exclusively for lower limb exoprosthetic fit­
English
tings.
2.2 Area of application
The product must be used in TF prostheses only.
Approved for a body weight of up to 125 kg.
2.3 Environmental conditions
Socket attach­
5R1=1, 5R1=2, 5R1=6, 5R2, 5R6=1, 5R6=2,
ment block
5R6=3
Socket adapter
4R22, 4R37, 4R51, 4R55, 4R95
Storage and transport
Temperature range –20 °C to +60 °C (–4 °F to +140 °F), relative
humidity 20 % to 90 %, no mechanical vibrations or impacts
Allowable environmental conditions
Temperature range: –10 °C to +45 °C (14 °F to 113 °F)
Moisture: relative humidity: 20% to 90%, non-condensing
Unacceptable environmental conditions
Chemicals/liquids: fresh water, salt water, perspiration, urine,
acids, soapsuds, chlorine water