Storage; Compressor Element Overhaul; Liability; Problem Solving - Atlas Copco PTS 916 Cd Instruction Manual

Table of Contents

Advertisement

PTS 916 Cd

5.18 Storage

Run the compressor regularly, e.g. twice a week, until warm.
Load and unload the compressor a few times to operate the
unloading and regulating components. Close the air outlet valves
after stopping.
If the unit is going to be stored without running from
time to time, protective measures must be taken.

5.19 Compressor element overhaul

When a compressor element is due for overhaul, it is recommended
to have it done by Atlas Copco. This guarantees the use of genuine
parts and correct tools with care and precision.

5.20 Liability

The manufacturer does not accept any liability for any damage
arising from the use of non-genuine parts and for modifications,
additions or conversions made without the manufacturer's
approval in writing.
50
6

Problem solving

6.1 Problem solving chart

The chart helps to solve mechanical and electrical problems.
It is assumed that the engine is in good condition and that there is
adequate fuel flow to the filter and injection equipment.
!
An electrical fault must be traced by an electrician.
Make sure that the wires are not damaged and that they are clamped
tight to their terminals.

6.2 Battery and alternator precautions

– Never reverse the polarity of the battery or the alternator.
– Never break any alternator or battery connections while the engine
is running.
– When recharging the battery, disconnect it from the alternator.
Before using booster cables to start the engine, be sure of the
polarity and connect the batteries correctly.
– Never operate the engine without the main or voltage sensing cables
connected in the circuit.