PTS 916 Cd
These parameters are:
– Compressor status
– Engine RPM
– Set RPM
– Air discharge pressure
– Set pressure
– LP intercooler pressure
– MP intercooler pressure
– Compressor oil pressure
– Engine oil pressure
– Engine fuel pressure
– Ambient temperature
– LP element temperature
– MP element temperature
– HP element temperature
– Compressor oil temperature
– Air discharge temperature
– Air discharge temp. Setting
– Air disch. Temp. Valve pos.
– Coolant temperature
– Fuel temperature
– Fuel level
– Engine fuel consumption
– Battery voltage
– Loading valve status
– Engine power contact
– Starter engine status
– Oiler valve status
– Blow-off valve status
– Flap lock solenoid
– Engine load
– Engine boost pressure
– Air inlet temperature
38
Other actions and signals have no effect in this status.
S
Shutdowns
A
Time-out
A
Emergency Stop button
↓-button
A
↑-button
A
A
Return button
A
Stop command
Other actions and signals have no effect in this status.
4.5 During operation
Regularly carry out following checks:
– Check alarm lamp at the front and alarm lamp and horn at the back
of the unit.
When starting up the unit and also when a shutdown occurs, the
alarm lamps and the horn will be activated. But when a warning
occurs, only the lamps will be activated.
– Check the air filter service indicator.
If the yellow signal shows in the window of the indicator (see
section 5.4.3), clean or replace the filter elements.
– Check the air outlet temperature of the MP compressor element.
4.6 Stopping instructions
– Close the air outlet valve(s).
– On the User Interface, push the function button below the indication
Noload.
– Push the Stop button.
The pressure is not immediately relieved from the
!
unit, when the Stop button is pushed.
– Once the engine has stopped, switch the control panel power switch
to the OFF position.
– Turn OFF the battery switch.
R
To Shutdown status (see section
4.4.12)
R
Back to active compressor status
R
To Emergency Stop status (see
section 4.4.13)
R
Scroll text down
R
Scroll text up
R
Back to active compressor status
R
Same function as in the active
compressor status
Preliminary