User Interface And Compressor Control Module; Look Of User Interface; Control - Atlas Copco PTS 916 Cd Instruction Manual

Table of Contents

Advertisement

3
User Interface and Compressor
Control Module

3.1 Look of User Interface

The User Interface consists of a color LCD display which gives the
user the essential process information feedback.
Any mix-up of buttons and button functions is reduced to an
absolute minimum thanks to an ergonomic design, which has as
few buttons as possible.
7
8
6
1
Running hours and warning bar. When warnings occur, they swap with
the running hours on this bar, showing the next message every 3
seconds.
2
Setpressure bar
3
Additional information bar
4
Compressor status bar
5
Button function bar
6
Air discharge pressure and shutdown information bar
7
Fuel bar
8
This is what the fuel level bar would look like if you hook up external
fuel supply.
The User Interface is built in into the side of the rear right corner
panel, with an emergency stop button directly underneath, for
maximum safety during the cranking procedure.
Preliminary
1
2
3
5
4

3.2 Control

Arrow buttons
The arrow buttons are generally used to increase or decrease the
setpressure.
In the Process Info status however, they are used to scroll the text
up and down the screen, and in the Options status they are used to
change the user parameters.
Control modes
The CCM can be controlled via three different control modes:
Local control mode
The CCM is controlled by means of the UI. The Control Mode
parameter is Local when the Remote parameter is disable or disable
lock.
The Local control mode is the default mode.
Remote control mode
The CCM is controlled by means of the remote inputs; the remote
control connector is located at the back of the UI.
The Control Mode parameter is Remote when the Remote
parameter is enable or enable lock.
1
Remote
2
Internal lights
3
Heaters
4
Harness connector
When this control mode is active, monitoring the operation on the
UI stays possible. Further, the UI can only be used for looking at
the System information and the Process information, and for
changing parameters in the Options status.
PC control mode
The CCM is controlled by means of a PC. This control mode can
only be selected with the Connect button on the PC. When the
button is clicked, the Control Mode parameter becomes remote PC,
regardless of the state of the Remote parameter. Changing the
Remote parameter will not effect the Control Mode parameter until
the Disconnect button is clicked.
Instruction manual
PC
DDR
1
1
1
2
0
0
3
4
21