Options Status; Process Info Status - Atlas Copco PTS 916 Cd Instruction Manual

Table of Contents

Advertisement

4.4.15 Options status

In this status, the operator can change the parameters for which he
has clearance.
The Rental companies can deny access to the gray parameters for
the operator.
In that case, the parameters are not shown on the screen.
With the arrow buttons, a parameter is selected.
Parameters which toggle between different settings (e.g.: Pressure
Units), can be changed by pressing the Toggle button.
Other parameters (e.g.: Display Luminosity) can be changed by
pressing the Edit button.
After changing the value with the arrow buttons, the new value
needs to be confirmed with the OK button.
A
Return button
The parameters the operator can change are:
– Display Luminosity
– Pressure Units (Metric/Imperial)
– Temperature Units (Metric/Imperial)
– Flow Units (Metric/Imperial)
– Start method (if Autostart = enable or disable)
– Autostart pressure (if Autostart = enable or enable lock)
– Stop method (if Autostop = enable or disable)
– Autostop time (if Autostop = enable or enable lock)
– Control mode (if Remote = enable or disable) (Local/Remote)
– Air discharge temperature control (if Air Discharge Temperature
Control Parameter = enable or disable)
– Air discharge temperature setpoint (if Air Discharge Temperature
Control Parameter = enable or enable lock)
– Reload/Unload pressure (if enabled)
Other actions and signals have no effect in this status.
Preliminary
R
To Ready for Start status (see
section 4.4.2)

4.4.16 Process Info status

Two key access
Depending on the setting of the Infobutton parameter, the operator
has access to the Process Info status by pressing a single named
function key, the Process Info button. In that case the Infobutton
parameter is enable.
When the Infobutton parameter is disable, the access to the Process
Info status is made by a two button function.
While pressing the unnamed function button, which otherwise would
be the Process Info button, the other function button has to be
pressed.
The Infobutton parameter can be changed with the PC, Rental
companies clearance.
Process Info status function
This status is not an active status, but can be entered from the
following statuses:
– Standby status
– Permissive Start status
– Cranking status
– Warmup status
– Noload status
– Load/Unload status
– Cooldown status
– Shutdown status
– Start Failure status
– Emergency Stop status
The Process Info status gives a summary of all parameters
measured by the CCM, and those taken from the ECM's dataline.
Instruction manual
37