PTS 916 Cd
When the PC mode is active, monitoring the operation on the UI
stays possible. Further, the UI can only be used for looking at the
System information and the Process information.
Control commands
Start command
Local: Pressing the Start button on the UI.
Remote: Activating the Remote Start input.
PC: Clicking the Start button on the PC.
Stop command
Local: Pressing the Stop button on the UI.
Remote: Activating the Remote Stop input.
PC: Clicking the Stop button on the PC.
Load command
Local: Pressing the Load button on the UI.
Remote: Activating the Remote Load input (when not loaded).
PC: Clicking the Load button with the mouse.
Noload command
Local: Pressing the Noload button on the UI.
Remote: Activating the Remote Load input (when loaded).
PC: Clicking the Noload button with the mouse.
22
Enable parameters
There are four enable parameters with four possible conditions.
The lock extension gives the Rental companies the possibility to
prohibit the operator from changing the parameters via the UI, thus
restricting the operator to one condition of the parameter.
Parameter
E/D
Lock
Autostart
enable
disable
Autostop
enable
disable
Remote
enable
disable
Air Discharge
enable
Temperature
disable
Regulation
Re/Unload
enable
Control
disable
Unload RPM
enable
Control
disable
CCM operation
x
Automatic start
x
Manual start
x
Automatic stop
x
Manual stop
x
Remote Control Mode
x
Local Control Mode
x
Air Disch. Temp. Control activated
x
Air Disch. Temp. Control not active
-
Re/Unload press. adjustable with UI
-
Re/Unload press. not adjustable with
UI
-
Unload RPM adjustable with UI
-
Unload RPM not adjustable with UI
Preliminary