Fluid refrigerant will also cause freezing of the eyes; always wear safety glasses.
Refrigerant is harmful. Do not inhale refrigerant vapours. Check that the working area is
adequately ventilated.
Be aware that certain components such as the refrigerant compressor and the discharge pipe can
become quite hot (up to 110 °C - 230 °F). Therefore, wait until the dryer has cooled down before
removing the panels.
Before starting any maintenance or repair work, switch off the voltage and close the air inlet and
outlet valves.
Local legislation
Local legislation may stipulate that:
Work on the refrigerant circuit of the cooling dryer or on any equipment which influences its
function must be undertaken by an authorised control body.
The installation should be checked once a year by an authorised control body.
General
For all references see section Introduction.
The following remarks should be kept in mind:
Keep the dryer clean.
Brush or blow off the finned surface of condenser monthly.
Stop the compressor, close the air outlet valve and switch off the voltage.
Remove any dirt on the condenser inlet with a vacuum cleaner.
Next, clean with an air jet in the reverse direction to normal flow. Use low pressure air. If
necessary, the pressure may be increased up to 6 bar(e) (87 psig).
Clean the condenser area with a vacuum cleaner.
Inspect and clean the electronic condensate drain monthly.
7.9

Service kits

Service kits
For overhauling and for preventive maintenance, a wide range of service kits is available. Service
kits comprise all parts required for servicing the component and offer the benefits of genuine parts
while keeping the maintenance budget low.
Also a full range of extensively tested lubricants, suitable for your specific needs is available to
keep the compressor in excellent condition.
Consult the Spare Parts List for part numbers.
7.10

Storage after installation

Procedure
Run the compressor regularly, e.g. twice a week, until warm. Load and unload the compressor a
few times.