4.4.11 Start failure status

First a stopping procedure is executed, and the operator has to wait.
Sreen A: Start failure, origin in Permissive start status.
Sreen B: Start failure, origin in Cranking status.
S
Warnings
A
Emergency Stop button
↓-button, press once
A
↑-button, press once
A
↓-button, press continuously
A
↑-button, press continuously
A
A
Power OFF switch
A
Reset button
Other actions and signals have no effect in this status.
Preliminary
R
Are shown on the screen
R
To emergency Stop status (see
section 4.4.13)
R
Set pressure - 0.1 bar
R
Set pressure + 0.1 bar
R
Set pressure - 0.1 bar/second
R
Set pressure + 0.1 bar/second
R
End of operation
R
To Ready for Start status (see
section 4.4.2)

4.4.12 Shutdown status

First a stopping procedure is executed.
S
Warnings
A
Emergency Stop button
↓-button, press once
A
↑-button, press once
A
↓-button, press continuously
A
↑-button, press continuously
A
A
Power OFF switch
A
Reset button
Other actions and signals have no effect in this status.
Instruction manual
R
Are shown on the screen
R
To emergency Stop status (see
section 4.4.13)
R
Set pressure - 0.1 bar
R
Set pressure + 0.1 bar
R
Set pressure - 0.1 bar/second
R
Set pressure + 0.1 bar/second
R
End of operation
R
To Ready for Start status (see
section 4.4.2)