Heater Engine Installation - Masonry; Masonry Installation Overview; Masonry Installation - Detail - Rinnai RIBF25N Operation & Installation Manual

Gas log flame fire
Table of Contents

Advertisement

HEATER ENGINE INSTALLATION - MASONRY

MASONRY INSTALLATION OVERVIEW

Read this manual thoroughly and gain a full understanding of the requirements before
undertaking installation.
IMPORTANT
Ensure gas supply to heater is turned off for the first stages of this instruction.
Step 1.
Prepare Site - p.18
Step 2.
Unpack The Heater Engine - p.18
Step 3.
Preparing Heater Engine - p.18
Step 4.
Positioning the Heater Engine - p.19
Step 5.
Connect Electrical Supply - p.19

MASONRY INSTALLATION - DETAIL

Step 1. Prepare Site
Ensure the intended enclosure meets the requirements of the dimensions as stipulated in
"ENCLOSURE REQUIREMENTS" on page 14 and that gas and electrical supplies have been
IMPORTANT
prepared in accordance with the dimensions stipulated in "GAS SUPPLY" on page 15 and
"ELECTRICAL SUPPLY" on page 15.
Step 2. Unpack The Heater Engine
The heater engine is supplied in one carton, check to ensure you have all contents as listed on "BEFORE YOU
START" on page 1 at the start of this manual before proceeding.
Carefully remove carton by removing the straps and lifting the carton off the appliance. Remove all packaging
materials and check all components for damage. If ANY damage is evident DO NOT install or operate this
appliance. Contact your supplier for advice.
Retain the cardboard carton for use in the "Positioning the Heater Engine" on page 19.
HINT
Before installing the heater, check it is the correct gas type, (refer to the gas type label on the top body panel of the
heater). Refer to the local gas authority for confirmation of gas type if you are in doubt.
Step 3. Preparing Heater Engine
Attach the adhesive backed foam sealing strip
Ensure the seal is stuck to the Fascia Assembly mounting panel at approximately 20mm from the top edge
The foam strip is intended to form a seal between the heater and the fireplace brickwork. If an adequate seal cannot
be formed then another means of sealing must then be used. (e.g. non combustible insulation or heat resistant
silicon).
Remove (do not discard) the gas/electrical access plate
Rinnai Australia
supplied to rear face of the fascia assembly mounting panel
A
A
C
B
Step 6.
Insert Heater Engine Into Fireplace - p.19
Step 7.
Connecting Gas - p.19
Step 8.
Leak Testing - p.19
Step 9.
Securing The Heater Engine - p.19
Step 10. Completing Heater Installation - p.19
five screws.
D
D
18
Slimfire 252 Operation & Installation Manual
.
B
.
C