4.6.2 Readout of analogue input data
[Function code:04(04H)]
Readout will be made for "Analogue input (2 byte:16 bit) data" whose numbers are continuous for
the specified number of values starting with the specified number. Data is divided into high 8 bits
and low 8 bits, which then will be arranged in the order of their numbers to form data for the reply
message. The example of reply is the same as the "Function code03". But the starting number
(relative number) is "Reference #-30001".
4.6.3 Write of analogue settings
[Function code:06(06H)]
The analogue setting with the specified number is made to the specified value.
Example: Setting the fixed temperature operation SV temperature of slave 1 to100.
〈RTU mode〉
Master→device
Slave address
Function code
Setting # (H)
Setting # (L)
Setting data (H)
Setting data (L)
CRC(L)
CRC(H)
〈Error check in the ASCII mode〉
LRC
Note: Setting number (relative number) is "Reference #-40001".
Note: Normal reply is the same as for the command message.
Device→master (normal)
01H
Slave address
06H
Function code
00H
Setting #(H)
00H
Setting #(L)
00H
Setting data (H)
64H
Setting data (L)
88H
CRC (L)
21H
CRC (H)
95H
LRC
42
4. Operating procedures
Setting external communication
01H
06H
00H
00H
00H
64H
88H
21H
95H