Ethernet Link; Tcp And Udp Service Ports - ABB FMBT-21 User Manual

Modbus/tcp adapter module
Table of Contents

Advertisement

70 Technical data
Degree of protection
Ambient conditions
Package
Indicators
Connectors
Power supply
General

Ethernet link

Compatible devices
Medium
Topology
Transfer rate
Serial communication type
Protocol
Number of connections

TCP and UDP service ports

There are multiple in-bound and out-bound network services running on the module.
Some ports are protocol-specific and are not used when other protocols are selected.
Port
Service
80 (TCP)
HTTP
502 (TCP/UDP)
Modbus/TCP
68 (UDP)
DHCP
IP20
The applicable ambient conditions specified for the drive in its
manuals are in effect.
Cardboard. Plastic wrapping: Antistatic air bubble sheet (PE).
Three bicolor LEDs (HOST, MODULE, NETWORK/NET)
A 20-pin connector to the drive
RJ-45 connector to Ethernet (X1)
RJ-45 connector for chaining another adapter module (X2)
+3.3 V ±5% max. 400 mA (supplied by the drive)
Complies with EMC standard EN 61800-3:2004
Printed circuit board conformal coated
Ethernet Standard IEEE 802.3 and IEEE 802.3u devices.
10BASE-TX or 100Base-TX with Auto-negotiation and Auto-MDIX
(Auto-crossover)
• Wiring: CAT5e/6 S/FTP, CAT5e/6 S/STP, CAT5e/6 SF/FTP
• Connector: RJ-45
• Termination: Internal
• Maximum segment length: 100 m / 328 ft
Bus or star.
In a chain maximum recommended amount of nodes is 50.
10 Mbps or 100 Mbps
Half or full duplex
Modbus/TCP
Two
Purpose
Used for Ethernet tool communication. To disable, go to
vice configuration page (page 86)
Communication between the drive and a PLC.
Note: Used only when Modbus/TCP protocol is selected
DHCP client
Note: Used only when IP configuration method is selected as
"Dyn IP DHCP".
Ser-
via web interface.