RT530E-2 SERVICE MANUAL
Outrigger Control Valves
Description
There are four valve assemblies responsible for controlling
the outrigger system, the integrated outrigger/rear steer
valve, the front and rear outrigger control manifolds, and the
pilot operated check valves.
NOTE:
For a more detailed description and maintenance
of the valves, refer to Valves in Section 2 -
HYDRAULIC and PRESSURE SETTINGS.
Pilot Operated Check Valve
The pilot operated check valves are located in the outrigger
jack port blocks. The check valve provides two functions; the
GROVE
first function is a holding valve, the second function provides
a thermal relief of the jack.
Integrated Outrigger/Rear Steer Manifold
The integrated outrigger/rear steer valve is mounted on the
frame center section to the rear of the front axle. Refer to
Section 2 - HYDRAULIC and PRESSURE SETTINGS.
Outrigger Control Manifold
The front and rear outrigger control manifolds are located
on the respective outrigger boxes. Each manifold consists of
four 2-position, 2-way solenoid valves.
Published 4-22-15, Control # 556-00
UNDERCARRIAGE
8-35
8
Need help?
Do you have a question about the Grove RT530E-2 and is the answer not in the manual?