Attaching a management station

NOTE
DC return must be isolated from the device ground (DC-I) when connecting to the power supply.
This equipment installation must meet NEC/CEC code requirements. Consult local authorities for regulations.

Removing NetIron XMR 32000 router DC power supplies

Follow these steps to remove a 2400W DC power supply in a NetIron XMR 32000 router:
1.
Ensure the main DC power breaker is OFF.
2.
Use a #1 Phillips screwdriver to remove the screws that secures the safety cover, as shown in
the safety cover.
3.
Use a #2 Phillips screwdriver to remove the screws securing the power lugs. Refer to
4.
Pull down on handle to remove power supply. Refer to
Follow these steps to remove a 3000W DC power supply in a NetIron XMR 32000 router:
1.
Ensure the main DC power breaker is OFF.
2.
Use a #1 Phillips screwdriver to remove the screw that secures the safety cover, as shown in
3.
Pull down on the handle to remove the 3000W power supply. Refer to
4.
Use a #2 Phillips screwdriver to remove the screws securing the power lugs. Refer to

Final steps

Follow these steps in the order listed to complete the installation:
"Attaching a management station"
"Activating the power source"
"Verifying proper operation"
Attaching a management station
You can manage your router in the following ways:
Connect a PC or terminal to the console port on the management module. From this port, you can assign an IP address to the
management module and establish connections through Telnet or SSH.
Connect the router to your existing management network and manage the router and other network devices from a management
station.
NOTE
The management network that you connect to through the 10/100 Ethernet port must be separate and isolated from the
network over which user packets are switched and routed. For information about functionality on the management port,
Refer to
"Understanding management port functions"
184
Figure 130
on page 180.
Figure 130
on page 206.