Enabling A Power Supply Shutdown - Brocade Communications Systems MLX Series Installation Manual

Supporting netiron os 6.0.00
Hide thumbs Also See for MLX Series:
Table of Contents

Advertisement

Replacing a power supply
module 3 ni-mlx-48-port-1g-mrj21
!
!
!
no logging enable ntp
logging console
telnet login-retries 5
telnet server
power-supply monitoring threshold 32
username script password 8 $1$hR/..5B1$adiszoS76gLD9zIyFF1ER1
In the example above, the configured power supply monitoring threshold is 32 cycles per hour.
Use the following command to show the uptime of modules:
Brocade#show version | include time
Active Management uptime is 9 minutes 30 seconds
Standby Management uptime is 8 minutes 45 seconds
LP Slot 3 uptime is 8 minutes 48 seconds
LP Slot 4 uptime is 8 minutes 48 seconds
LP Slot 5 uptime is 8 minutes 50 seconds
LP Slot 6 uptime is 8 minutes 50 seconds
LP Slot 8 uptime is 8 minutes 48 seconds
Brocade#
Brocade# show version | include xmr
Compiled on Jul
9 2012 at 09:52:52 labeled as xmr05400b396
Compiled on Jul
9 2012 at 09:52:52 labeled as xmr05400b396
Brocade#
The show power-supply-monitoring command displays the last 32 recorded failure timestamps for a power supply. The displayed
failure timestamp is the number of seconds since the last system reboot. The current configured power supply monitoring threshold value
is also displayed at the end of the output.
Syntax: show power-supply-monitoring

Enabling a power supply shutdown

NOTE
The power-on power supply and power-off power-supply commands are not available on some power supplies. These
commands can be useful for Brocade Technical Support when troubleshooting a router. It is recommended you use the
commands only when troubleshooting a router with Brocade Technical Support.
NOTE
There is a 10 second delay between the power-off lp command and the power-on lp command. Wait 10 seconds between
commands.
The power-off power-supply command allows you to shut down a power supply manually.
To shut down a power supply, enter the following command.
Brocade# power-off power-supply 3
This will Shutdown The Power Supply # 3
Are you sure? (enter 'y' or 'n'): y
ERROR: Power Supply # 3 is the Last Available in the system and will not be shutdown.
To force the shutdown, please use keyword "forced"
Syntax: power-off power-supply [forced] <decimal>
The power-supply keyword allows you to shut down a power supply.
256
Brocade MLX Series and Brocade NetIron XMR Installation Guide
53-1004195-02

Advertisement

Table of Contents
loading

Table of Contents