FIGURE 25 Switch fabric module front panel
l
The front panel contains two LEDs, as described in <Link>Table 16.
TABLE 16
Switch fabric module LEDs
LED
Position
Pwr
Above Active LED
Active
Below Pwr LED

High-speed switch fabric modules

NOTE
Gen-1 switch fabric modules and Gen-2 high-speed fabric (HSF) modules are not compatible and will not operate together in the
same device.
HSF modules are supported on Brocade MLX Series and NetIron XMR routers, and are interoperable with all existing interface modules.
HSF modules are hot-swappable, which means you can install or replace them while the system is powered up and running.
NOTE
Do not remove or power-off all switch fabric modules on MLX chassis while the device is up and running. Removing all the switch
fabric modules from the device and then re-inserting them can cause the device to become unstable, resulting in protocol flaps
and thereby traffic impact. A system reload is required to recover.
HSF modules can operate in normal mode or turbo mode but will boot in turbo mode only if all active interface modules are Gen-2 and
Gen-3modules.
Brocade MLX Series and Brocade NetIron XMR Installation Guide
53-1004195-02
DRAFT: BROCADE CONFIDENTIAL
State
Meaning
On
The module is receiving power.
Off
The module is not receiving power.
On
The switch fabric is on (active) and ready to switch user
(4-, 8-, and 16-slot
packets.
routers only)
On (32-slot routers
The switch fabric is on (active) and ready to switch user
only)
packets.
Blinking
The switch fabric is on (active) and being accessed by
(32-slot routers only)
the Management Module CPU. This indicates normal
operation.
NOTE: On devices supporting software version
Off for extended
The switch fabric is not active and cannot switch user
period
packets.
R05.3.00 and earlier, when you insert an SFM
or during powering on the device, the Active
LED was off for a short duration, up to 15
seconds because the monitoring of the Fabric
module is stopped for this duration. After this
delay, the LED indicated the monitoring status.
In version R05.4.00 and later, the Active LED
reads the switch fabric continuously even
during module insertion or powering on the
device, and thus the Active LED blinks.
Router modules
31