Hardware specifications for NetIron XMR routers
Brocade MLX router operating environment
TABLE 46
Operating temperature
(0° – 40°C) 32° – 104°F
Storage environment
The following table provides the storage environment specifications for the Brocade MLX routers.
Brocade MLX router storage environment
TABLE 47
Storage temperature
(-25°– 70°C) -13° – 158° F
Safety agency approvals
•
CAN/CSA-C22.2 No. 60950-1-07/UL60950-1 – Second Edition, Safety of Information Technology Equipment
•
EN 60825-1 Safety of Laser Products – Part 1: Equipment Classification, Requirements and User's Guide
•
EN 60825-2 Safety of Laser Products – Part 2: Safety of Optical Fibre Communications Systems
•
EN 60950-1:2006\IEC 60950-1:2005, Second Edition, Safety of Information Technology Equipment
Electromagnetic approvals
•
FCC Part 15, Subpart B (Class A)
•
EN 55022 (CE mark) (Class A)
•
EN 55024 (CE mark) (Immunity) for Information Technology Equipment
•
ICES-003 (Canada) (Class A)
•
AS/NZ 55022 (Australia) (Class A)
•
VCCI (Japan) (Class A)
•
EN 61000-3-2
•
EN 61000-3-3
•
EN 61000-6-1
Hardware specifications for NetIron XMR routers
The following sections describe hardware specifications for NetIron XMR routers.
Power specifications
The following power supply frequency requirements apply to NetIron XMR 4000, 8000, and 16000 routers:
•
AC Input Rating: 100 to 240V, 50/60 Hz, 16.0 A maximum per power supply
•
AC Operating Voltage Range: 90 - 264V, 50/60 Hz
•
Inrush current: 40A peak maximum at 25 degrees C (77 degrees F)
280
Relative humidity
5 to 90%, at (40°C) 104°F, non-condensing
Storage humidity
95% maximum relative humidity,
non-condensing
Operating altitude
(0 – 2012 meters) 0 – 6600 ft
Storage altitude
(0 – 4500 meters) 0 – 15,000 ft
Brocade MLX Series and Brocade NetIron XMR Installation Guide
53-1004195-02