Installing a Brocade MLX-16 router

For the NEBS-compliant installation of Brocade MLXe-32, routers with AC and DC systems, use a ground
wire of at least 2 American Wire Gauge (AWG). The ground wire should have an agency-approved crimped
connector (provided with the device) attached to one end, with the other end attached to building ground.
The connector must be crimped with the proper tool, allowing it to be connected to both ground screws on
the enclosure. Before crimping the ground wire into the provided ground lug, ensure the bare copper wire
has been cleaned and antioxidant is applied to the bare wire.
To ensure adequate bonding when attaching the ground lug, a minimum of 20 PSI of torque is required to
be applied to the mounting hardware used to attach the ground lug.
FIGURE 50 Crimping the power supply wire in the lug
1
AWG power supply wire:
#8 AWG wire for 1200W power supply
#6 AWG wire for 1800W power supply
4.
Connect the -48V cable to the negative terminal and the 0V cable to the positive terminal.
NOTE
DC return must be isolated from the router ground (DC-I) when connecting to DC power supplies.
5.
Replace the transparent cover.
This equipment installation must meet NEC/CEC code requirements. Consult local authorities for regulations.

Final steps

Complete these final steps in the order listed:
"Attaching a management station"
"Activating the power source"
"Verifying proper operation"
Installing a Brocade MLX-16 router
This section describes how to install a Brocade MLX-16 router.
64
DRAFT: BROCADE CONFIDENTIAL
Brocade MLX Series and Brocade NetIron XMR Installation Guide
53-1004195-02