Converting a floorstand model to a rack model
Removing the accessible drive cage
▶ Remove the front panel module, see
page
465.
▶ If applicable, remove all accessible drives, see
drive" on page
▶ If applicable, remove an HDD extension box, see
page
265.
Figure 345: Removing the accessible drive cage (A)
▶ Remove the two screws (see circles) from the bottom side of the server.
▶ Bring the server back to its horizontal position.
At least two people are needed to turn over a completely equipped
server. Remove HDDs and PSUs in order to facilitate the task.
534
441.
Upgrade and Maintenance Manual
"Removing the front panel module" on
"Removing an accessible
"HDD extension box" on
TX2550 M5