Fujitsu PRIMERGY TX2550 M5 Upgrade And Maintenance Manual page 194

Hide thumbs Also See for PRIMERGY TX2550 M5:
Table of Contents

Advertisement

Hard disk drive (HDD) / solid state disk (SSD)
▶ Connect the following cables to the HDD backplane 1 in the following
sequence:
1 SAS cable from connector "MLC1" on SAS controller to connector
"X9"
2 Power cable from connector "PWR1" on system board to connector
"X40"
If applicable, to an additional accessible drive to connector "X17" or
connector "X18"
If applicable, connect the OOB cable, see
on page
554.
For the cable plan, see
Concluding steps
▶ Install the fan bridge, see
"Installing the system air duct" on page
▶ Insert all HDD modules, see
page
178.
Make sure that you reinstall the HDD module in the bay it was located
before the HDD backplane replacement.
▶ Insert all dummy modules, see
page
181.
"Reassembling" on page
"Connecting the power cord" on page
"Switching on the server" on page
194
"Appendix B" on page
"Handling the fan bridge" on page
68.
"Installing a 3.5-inch HDD module" on
"Installing a 3.5-inch dummy module" on
68.
82.
83.
Upgrade and Maintenance Manual
"Replacing the OOB cable"
589.
92.
TX2550 M5

Advertisement

Table of Contents
loading

Table of Contents