SamplexPower Evolution Series Owner's Manual page 82

Inverter/charger
Hide thumbs Also See for Evolution Series:
Table of Contents

Advertisement

SECTIOn 6 |
tAbLe 6.5 ProgrAMMAbLe AnD DeFAuLt PArAMeterS - grouP "inPut high LiMit"
group
Parameter name
reSet VoLtAge
Cut oFF Point 1
DeteCt tiMe 1
inPut -
Cut oFF Point 2
high LiMit
DeteCt tiMe 2
Cut oFF Point 3
DeteCt tiMe 3
tAbLe 6.6 ProgrAMMAbLe AnD DeFAuLt PArAMeterS - grouP "other FunCtionS"
Parameter name
"Power SAVing"
– "enter Point"
– "wAke uP Point"
"reMote SwitCh"
– for ON /Off control
through external 12V
signal fed to remote
ON / Off terminals on
the front Panel (15,
fig 2.1)
"reLAy FunCtion"
(for Status relay)
82 | SAMLEX AMErICA INC.
Operation, Protections and Troubleshooting
eVo-
2212e
Setting range
eVo-
eVo-
2212e
3012e
1 = Enable 0 = Disable
4 – 50W
5 – 50W
0 = button type: 12V signal is fed
through Push button Type of Switch
– Pressing of Push button > 2 sec
will switch the unit ON
– When ON, pressing Push button
> 5 sec will turn the unit Off
1 = Switch type: 12V signal is fed
through contacts of Toggle Type of
Switch or relay contact
– ON condition (contacts closed)
will turn the unit ON
– Off condition (contacts open)
for 2 sec will switch the unit Off
0 = Charge / other
– Off in "Charging" Mode
– ON in other Modes i.e. "Inverting",
"Power Saving" or "Standby"
1 = normal / Fault
– Off in normal operating conditions
– ON in fault Modes
2 = generator 0
– ON when batteries drop to "LOW
VOLT ALArM" or lower for period
= "GS DETECT TIME" - Initiates
Generator start
– Off after batteries are completely
charged till float Stage - initiates
Generator stop
Setting range
eVo-
eVo-
eVo-
3012e
2224e
4024e
200.0 – 280.0V
200.0 – 280.0V
0 – 2000 cycle
200.0 – 280.0V
0 – 2000 cycle
200.0 – 280.0V
0 – 2000 cycle
eVo-
eVo-
2224e
4024e
2212e
CAution! ON/Off Logic also controls the
operation of the ON/Off button on the front
panel (11, fig 2.1). The Default setting is
"button Type".
If the ON/Off Control is changed to external
"remote Switch", it will not be possible to
switch ON/Off the EVO
from the front panel ON/Off Push button
because it will work with Switch Type Logic.
It will be ON only as long as the Push buttom
is kept pressed and will switch Off when
released.
Default value
eVo-
eVo-
2212e
3012e
260.0V
265.0V
300 cycle
270.0V
60 cycle
275.0V
1 cycle
Default Value
eVo-
eVo-
3012e
0 = Disable
6W
8W
7W
10W
0 = button Type
TM
2 = Generator 0
eVo-
eVo-
2224e
4024e
eVo-
eVo-
2224e
4024e
6W
8W
7W
10W
Inverter/Charger

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evo-2212eEvo-3012eEvo-2224eEvo-4024e

Table of Contents