The AC input / output wiring terminals are intended for field connection using Copper
conductors that are to be sized based on 70°C. See Tables 3.2.1, 3.2.2 and 3.2.3 for
sizing of conductors for AC INPUT circuits and Table 3.3 for sizing of conductors for AC
OUTPUT circuits.
7.
Over current protection (AC breakers) for the AC input / output circuits has NOT been
provided and has to be provided by the installer / user. See guidelines at Tables 3.2.1,
3.2.2 and 3.3.3 for sizing of breakers for AC INPUT circuits and Table 3.3 for sizing of
breakers for AC OUTPUT circuits. National and Local Electrical Codes will supersede
these guidelines.
8.
The battery terminals are intended for field connection using Copper conductors that are
sized based on 90°C. See Table 3.1 for recommended sizes for installation.
9.
Over current protection (fuse) for battery and External Charger circuits has NOT been
provided and has to provided by the installer / user. See guidelines at Table 3.1 for
recommended sizes for installation. National and Local Electrical Codes will supersede
these guidelines.
10. Tightening torques to be applied to the wiring terminals are given in Section 3.7.2.
11. This unit has been provided with integral protections against overloads.
12. WArNING! To reduce risk of electric shock and fire:
Installation should be carried out by certified installer and as per Local and National
Electrical Codes.
Do not connect to circuit operating at more than 280 Volts to Ground.
both AC and DC voltage sources are terminated inside this equipment. Each circuit
must be individually disconnected before servicing.
Do not remove cover. No user serviceable part inside. refer servicing to qualified
servicing personnel.
Do not mount in zero clearance compartment.
Do not cover or obstruct ventilation openings.
fuse(s) should be replaced with the same type and rating as of the original installed
fuse(s).
13. GrOUNDING: The Grounding symbol shown below is used for identifying only the field
wiring equipment-grounding terminal. However, this symbol is usable with the circle
omitted for identifying various points within the unit that are bonded to Ground.
Grounding Symbol / Défaut à la terre
14. Precautions When Working With batteries.
batteries contain very corrosive diluted Sulphuric Acid as electrolyte. Precautions
should be taken to prevent contact with skin, eyes or clothing. Wear eye protection.
batteries generate Hydrogen and Oxygen during charging resulting in evolution of
explosive gas mixture. Care should be taken to ventilate the battery area and follow
the battery manufacturer's recommendations.
Never smoke or allow a spark or flame near the batteries.