SECTIOn 3 |
Terminal" of the premises "ME" which, in turn, is bonded to the Earth Ground through
the Ground rod or through the buried metallic pipe (water / gas). Similarly, the Earthing
Terminal "EG" of the Generator is also bonded to the Earth Ground through the Main
Earthing Terminal of the Premises "ME"
The terminals for AC Input Ground of EVO
terminal for AC Output Ground {OUTUT GND (11)} of EVO
the metal frame / chassis of the EVO
for proper operation of the residual Current Device (rCD) on the output side of the
generator, it is to be ensured that the Neutral of the generator is either bonded internally
to the frame / chassis of the generator or externally to the Earthing Terminal "EG" on
the generator. This will create a Neutral to Earth Ground bond in the generator (Neutral
of generator " frame / chassis of generator " Earthing Terminal "EG" on the generator
" Main Earthing Terminal "ME" of the Premises " Earth Ground). Also, this will ensure
that if a ground fault occurs, leakage current is able to return back to the Neutral of
generator winding through the Earth ground path for tripping of the rCD.
For typical Mobile installation (Please refer to Fig. 3.14)
All structural metallic parts of the frame of the motorhome / caravan which are acces-
sible from within the motorhome / caravan are electrically bonded together to ensure
protective equi-potential surfaces. Any such electrically bonded structural metallic parts is
termed "chassis" and is shown by symbol "
The Negatives of the battery System and the alternator are bonded to the "Chassis
(i) The Grounding Terminal "G" of the 230VAC, 16A Mains Inlet / Hook-up Connec-
tor (ii) bus bar "PE-b" for Protective Earth (PE) conductors of the Distribution Panel for
loads backed up by EVO
generator are all electrically bonded to the Main Earthing Terminal "ME" of the mo-
torhome / caravan which, in turn, is bonded to the "chassis
The terminals for AC Input Ground of EVO
minal for AC Output Ground {OUTUT GND (11)} of EVO
metal frame / chassis of the EVO
for proper operation of rCD on the output side of the generator, it is to be ensured that
the Neutral of the generator is either bonded internally to the frame / chassis of the gen-
erator or externally to the Earthing Terminal "EG" on the generator. This will ensure that
if a ground fault occurs, leakage current is able to return back to the Neutral of genera-
tor winding through the "Chassis
3.14 grounDing - DC SeCtion
DC side grounding involves bonding of the metal chassis of EVO, the metal chassis of the DC
Electrical Panel and the battery Negative Terminal to the Earth Ground in shore based instal-
lation or to the metal frame / "Chassis
case of a ground fault in the +12V / +24V circuit, the fuse in the +battery line blows to clear
the fault. This fuse in the +battery line has Ampere capacity matching the rated DC input
current of the EVO
Installation
and (iii) the metallic frame / Earthing Terminal "EG" of the
TM
TM
in Inverter Mode i.e. 150A to 400A depending upon the model of the
TM
{Grid GND (5) and GEN GND (8)} and the
TM
(G1)
TM
"
{Grid GND (5) and GEN GND (8)} and the ter-
TM
(This internal bonding is shown as "G1" in fig 3.12)
" path for tripping of the rCD.
" of the motorhome / caravan. This ensures that in
are all internally bonded to
TM
"
are all internally bonded to the
TM
SAMLEX AMErICA INC. | 49
"