SECtION 4 |
PoWeR SAVinG:
Enable or disable Power Saving Mode when in "Inverting Mode".
Up Key x 4
SELECT GROUP
CHARGE CURVE
OTHER FUNCTION
enteR Point:
If the value of power drawn by AC load falls to the "ENTER POINT" value for 5 sec, the unit
will enter "Power Save Mode".
Up Key x 4
SELECT GROUP
CHARGE CURVE
WAKe UP Point:
If the unit is in "Power Save Mode" and the value of the AC power of the load rises to "WAKE
UP POINT", the unit will quit "Power Save Mode" and will start operating in full voltage
"Inverting Mode".
Up Key x 4
SELECT GROUP
CHARGE CURVE
ReMote SWitCH:
This selection is used when ON/OFF control of EVO
external 12 VDC signal fed to Remote ON/OFF terminals on the Front Panel of EVO
Charger (15, Fig 2.1 in EVO
shown in Fig 4.8 below:
0 = Button Type:
1
st
12VDC input
> 2 sec will switch ON
EVO Inverter Charger
1 = Switch Type:
12VDC input is
available - Power On
Fig 4.8. on/off Logic Diagram for Remote Switch options
!
CAUtion!
On/Off Logic shown in Fig 4.8 also controls the operation of the On/Off Button on the front
panel of EVO
Inverter/Charger (11, Fig 2.1 in EVO
TM
Default Setting is "Button Type".
32 | SAMLEX AMERICA INC.
Parameter Setup
Enter Key
SELECT GROUP
POWER SAVING
0 = Disable
Enter Key
SELECT GROUP
POWER SAVING
OTHER FUNCTION
Enter Key
SELECT GROUP
POWER SAVING
OTHER FUNCTION
Inverter/Charger Owner's Manual) On/Off Logic Diagram is
TM
12VDC signal is fed through Push Button Type of Switch.
Momentary contact of Push Button > 2 sec will switch EVO Inverter Charger ON
After power ON,
12VDC input < 5 sec
will have no effect
Enter Key
KEY IN PASSWORD
0000
Password 8052
See Section 4.3.1
Up Key x 1
ENTER POINT
1 = Enable
EVO-2212, 2224 - 6W
EVO-3012, 4024 - 8W
Up Key x 2
WAKE UP POINT
1 = Enable
Inverter/Charger is desired through
TM
No 12VDC input
for 2 sec - Off
Inverter/Charger Owner's Manual). The
TM
POWER SAVING
0 = Disable
Enter Key
KEY IN PASSWORD
6W
0000
Password 8052
See Section 4.3.1
Enter Key
KEY IN PASSWORD
7W
0000
Password 8052
See Section 4.3.1
After power ON,
12VDC input > 5 sec
will switch OFF
EVO Inverter Charger
APPENDIX A