SECtION 4 |
4.3 PASSWoRD PRoteCtion FoR PARAMeteR CHAnGe
All parameters except Time and Date are protected with a Password. When the required
parameter screen is reached and is displayed and enter Key is pressed to modify the parameter
value, the system will request a 4-digit Password. the Password is 8052. Once you enter the
Password correctly, you don't need to enter the Password again until until any key is not pressed
for over 60 seconds. An example of Parameter setting is shown at Section 4.3.1 below:
4.3.1 example of Password Activation and Changing Bulk Current Setting for
eVo-2224e from Default Value of 40A to 50A
SELECT GROUP
CHARGE CURVE
BULK CURRENT
40 A
KEY IN PASSWORD
SELECT GROUP
0000
CHARGE CURVE
PASSWORD CORRECT
BULK CURRENT
40 A
PASSWORD ERROR!!
KEY IN PASSWORD
0000
BULK CURRENT
PASSWORD CORRECT
40 A
BULK CURRENT
PASSWORD ERROR!!
!
90 A
SELECT GROUP
WRITING...
BULK CURRENT
CHARGE CURVE
50 A
40 A
BULK CURRENT
WRITE SUCCESS!
BULK CURRENT
40 A
50 A
!
90 A
KEY IN PASSWORD
WRITE FAILURE!
WRITING...
0000
50 A
50 A
PASSWORD CORRECT
OUT OF RANGE!
WRITE SUCCESS!
90 A
50 A
SELECT GROUP
CHARGE CURVE
PASSWORD ERROR!!
BULK CURRENT
WRITE FAILURE!
50 A
SELECT GROUP
50 A
CHARGE CURVE
BULK CURRENT
BULK CURRENT
40 A
OUT OF RANGE!
40 A
BULK CURRENT
90 A
KEY IN PASSWORD
40 A
0000
BULK CURRENT
!
BULK CURRENT
90 A
KEY IN PASSWORD
50 A
0000
PASSWORD CORRECT
WRITING...
50 A
PASSWORD CORRECT
PASSWORD ERROR!!
WRITE SUCCESS!
50 A
PASSWORD ERROR!!
BULK CURRENT
40 A
WRITE FAILURE!
50 A
BULK CURRENT
BULK CURRENT
40 A
!
90 A
OUT OF RANGE!
90 A
BULK CURRENT
!
90 A
WRITING...
Parameter Setup
Starting from any of the 4 Operating Mode Screens (shown at Fig 3.1),
press enter key. Screen "SELECT GROUP, CHARGE CURVE" as shown
on the left will be displayed (Group 1 of "Select Group" Menu Map,
Fig 4.3)
Press enter key to access up to 18 Parameter Screens under Group 1
"Charge Curve", (Parameters are detailed at Table 4.4 and Fig 4.1)
Screen "BULK CURRENT, 40A" as shown on the left will be displayed
(Page 1 of Group 1 SELECT GROUP "CHARGE CURVE", Fig 4.1).
Default current setting of 40A or previously set value will be displayed.
Press enter Key to change Bulk Current parameter setting. A
Password will be requested.
Password consisting of 4 digits will be requested. 4 digits will be
displayed (with initial value 0000) with the cursor blinking on the first
digit (0) on the left. Use Up /Down Keys to scroll to number 8 for the
first digit "8" of the password. Momentarily press enter Key (Short
press). Digit 8 will be entered as the first digit of the Password and
the blinking curser will automatically move to the 2nd digit (0) to the
right. As the next digit in the Password "8052" is "0", momentarily
press enter Key (Short press) to enter "0" in the second digit.
The blinking cursor will automatically move to the 3rd digit (0). Use
Up /Down Keys to scroll to number 5 for the 3rd digit "5" of the
password "8052" and momentarily press enter Key (Short press).
The blinking cursor will automatically move to the 4th digit (0). Use
Up /Down Keys to scroll to number 2 for the 4th digit "2" of the
password "8052". Now keep the enter Key pressed continuously
for longer time (3 to 4 sec) to write the full password of 4 digits
i.e. "8052".
Flashes twice when Password is correct. (8052)
Flashes twice when Password is not correct.