(4) Soldering a contact
Temporarily solder each contact and core wire, and then solder the core wire on the contact.
When using a drain wire, attach a heat shrink tube on it after soldering.
(Note) Take care not to stick out the core wire from the contact.
Contact
Downloaded from
ManualsNet.com
Appendix 1. Cable and Connector Specifications
Take care to prevent solder from adhering to the edge of solder cup.
Connector name
Applicable contact
CM10-SP10S
CM10-#22SC-S1
CM10-SP2S
CM10-#22SC-S2
Drain wire
search engine
Applicable cable
AWG20 or less
AWG16 or less
A
Core wire
Heat shrink tube