9-1-3 Setting the output magnification
Set as follows to output with a unit other than the standard output unit.
(Example 1) When SV061 = 11 and SV063 = 2560
(Example 2) When SV062 = 11 and SV064 = 128
No.
Abbrev.
SV063 DA1MPY D/A output channel 1 output
SV064 DA2MPY D/A output channel 2 output
9-1-4 Current feedback analog output function
Use this function to measure the resonance frequency when adjusting machine resonance suppression
filter.
The phase current is output to the CN9
pin. Connect a high-speed waveform
recorder, etc. between the GND (pin 1)
and the phase current to be measured,
and observe the state.
6: L axis U-phase current FB
16: L axis V-phase current FB
7: M axis U-phase current FB
Downloaded from
ManualsNet.com
The position droop is output as a 0.1mm/V unit to D/A output channel 1.
The position droop is output as a 2mm/V unit to D/A output channel 2.
Parameter name
magnification
magnification
Set the speed loop gain (SV005: VGN1) to approx. 50 to 100, disconnect the
resonance filter, and measure the waveform while the axis is stopped.
search engine
9. Adjustment
Explanation
When "0" is set, the data is output with the standard output unit.
Set a value other than 0 to change the output unit.
The scale is set with a 1/256 unit. When 256 is set, the unit is the
same as the standard output unit.
20 ms
9 - 3
Setting range
-32768 to 32767
Current feedback: 9 crests
Machine
9 cycles
= 450 Hz
=
resonance
-3
20 x 10
s
frequency