SPEC2 Servo specification
Downloaded from
ManualsNet.com
Parameter name
In the vertical axis drop prevention time control, set the time constant used
Deceleration time
for the deceleration control at emergency stop. Set a length of time that
constant at
takes from rapid traverse rate (rapid) to stopping.
Normally, set the same value as the rapid traverse acceleration/deceleration
emergency stop
time constant.
When performing the SHG control, set this with S003 (PGN1) and SV004
SHG control gain
(PGN2).
When not performing the SHG control, set to "0".
Set this with SV049 (PGN1sp) and SV050 (PGN2sp) if you wish to perform
SHG control gain in
the SHG control in the spindle synchronous control (synchronous tapping,
spindle synchronous
synchronous control with spindle/C axis).
control
When not performing the SHG control, set to "0".
Not used. Set to "0".
Not used. Set to "0".
D/A output channel 1
Input the No. of the data to be output to the D/A output channel.
data No.
D/A output channel 2
data No.
D/A output channel 1
When "0" is set, the data is output with the standard output unit.
output scale
Set a value other than 0 to change the output unit.
The scale is set with a 1/256 unit. When 256 is set, the unit is the same as
D/A output channel 2
the standard output unit.
output scale
Not used. Set to "0".
These parameters are set automatically by the NC system.
System setting
parameter
F
sabs
0
1
2
3
4
5
6
2
7
8
9
A
B
C
D
E
F
(Note 1)When performing by semi ABS method of absolute position detection, set
(Note 2)Set 0 if there is no particular explanation for the bit.
search engine
8. Setup
Explanation
E
D
C
B
A
9
bit
Meaning when set to 0
sabs Setting for normal use
"1". Also set SV017/abs to "1".
8 - 22
8
7
6
5
4
3
2
Meaning when set to 1
Absolute position detection
semi ABS is valid(Note1)
Setting range
(Unit)
0 to 20000
(ms)
0 to 1200
(rad/s)
0 to 1200
(rad/s)
0
0
0 to 102
-32768 to
32767
(Unit: 1/256)