Press ✓ and "CS-1 ENTER DATE MM-DD-YY" shows in the left display. Use
4 4 ) )
the product buttons to set the date in the right display.
Press the down arrow and "CS-2 ENTER TIME" shows in the left display and
5 5 ) )
the time flashes in the right display. Use the product buttons to change the time.
Press the down arrow and "CS-2 ENTER TIME" shows in the left display, and
6 6 ) )
"AM" or "PM" flashes in the right display. use the left and right arrows to change
between "AM" or "PM".
Press the down arrow and "CS-3 TIME FORMAT" shows in the left display, and
7 7 ) )
"12-HR" or "24-HR" shows in the right display. Use the left and right arrows to
change between a 12 hours time format or a 24 hours time format.
Press the down arrow and "CS-4 DAYLIGHT SAVING TIME" shows in the left
8 8 ) )
display. Use the left and right arrows to choose the correct daylight saving time
for your area: 1.OFF; 2.US (2007 & after); 3. EURO; or FSA (US before 2007).
5 5 . . 4 4 D D a a t t a a C C o o m m m m & & H H e e a a t t C C o o n n t t r r o o l l
NOTE: Data communications and heat control settings are shown in Level 3 Program
Mode. To ensure proper operation of fryer, please consult Henny Penny Corp. before
changing any of these settigns. Fo more information on these functions, contact
Service Department at 1-800-417-8405, or 1-937-456-8405.
5 5 . . 5 5 T T e e c c h h M M o o d d e e
The Tech Mode has self-diagnostic information, which can be used by certified
technicians for troubleshooting purposes.
NOTE: Not all Tech Mode functions are discussed in this section. To ensure proper
operation of fryer, please consult Henny Penny Corp. before changing any of these
settings. For more information on these functions, contact Service Department at 1-
800-417-8405, or 1-937-456-8405.
To enter Tech Mode:
Press and hold the temp and info button for 5 seconds, until display shows
1 1 ) )
"LEVEL 3", followed by "ENTER CODE".
Enter code 1, 1, 2, 2, 1, 1, 2, 2 (first two product buttons). "A. TECH" "RESETS"
2 2 ) )
shows in the display.
Press the down arrow five times, and when display shows "F. TECH", press the
3 3 ) )
right ✓ buttons and "T-1 SOFTWARE" shows in the display, the first step of the
Tech Mode. Use the up and down arrows to toggle through the steps.
NOTE: Press the right "X" button twice, at any time, to return to normal
operation.