Henny Penny LVE-203 Technical Manual page 60

Open fryer reduced oil capacity
Hide thumbs Also See for LVE-203:
Table of Contents

Advertisement

Go to front of fryer control panel for vat with suspect probe, loosed retaining
4 4 ) )
screw with Philip's-head screwdriver and hinge control panel down.
Disconnect 12-pin connector at left side of control panel and place connector on
5 5 ) )
flat surface with the open side up.
Hold connector in place with one hand, use other hand to insert pocket knife
6 6 ) )
blade or other small sharp tool into connector notch to depress metal locking
tab.
Continue to hold locking tab down and pull lead wire out of the rear of connector
7 7 ) )
and remove probe from fryer.
Place nut and new ferrule on new oil level probe and insert probe into
8 8 ) )
compression fitting.
Locate temperature probe through pot wall.
9 9 ) )
Place gauge against pot wall as shows in
1 1 0 0 ) )
page
48
49.
Figure 7-1 Probe Assembly Install ,