7 7 . . 1 1 1 1 E E l l e e m m e e n n t t S S e e n n s s e e S S w w i i t t c c h h
This switch removes power to the element when the element is raised. If a constant
"E-31" "HEATING ELEMENTS ARE UP" is shown on display when elements are
lowered into vat, check element safety switch.
7 7 . . 1 1 1 1 . . 1 1 C C h h e e c c k k o o u u t t
Support control panel bottom with one hand, loosen retaining screw at control
1 1 ) )
panel top, slide panel down slightly to clear screw, push panel up, swing panel
top out and down.
Refer to decal on control panel back, locate P9 connector (left vat - split vat) or
2 2 ) )
P10 connector (full or right vat).
Pull connector from panel and using multimeter, check for continuity between
3 3 ) )
two appropriate pins (labeled "HEAT SWITCH"). With safety switch plunger
pushed in (element lowered), circuit should be closed. With element up, circuit
should be open. If switch is faulty, replace switch.
7 7 . . 1 1 1 1 . . 2 2 R R e e p p l l a a c c e e m m e e n n t t
Remove six screws and rear shroud.
1 1 ) )
Pull the wires from the switch.
2 2 ) )
S S H H O O C C K K H H A A Z Z A A R R D D T T o o a a v v o o i i d d e e l l e e c c t t r r i i c c a a l l
s s h h o o c c k k , , m m o o v v e e t t h h e e p p o o w w e e r r s s w w i i t t c c h h t t o o o o f f f f a a n n d d
d d i i s s c c o o n n n n e e c c t t m m a a i i n n c c i i r r c c u u i i t t b b r r e e a a k k e e r r , , o o r r u u n n - -
p p l l u u g g c c a a r r d d a a t t w w a a l l l l r r e e c c e e p p t t a a c c l l e e . .
53