Henny Penny LVE-203 Technical Manual page 14

Open fryer reduced oil capacity
Hide thumbs Also See for LVE-203:
Table of Contents

Advertisement

Display
"E-18-B"
"E-18-C"
"E-21"
"E-22"
"E-31"
"E-41"
"E-46"
"E-47"
"E-48"
"E-54C"
"E-60"
"E-62A"
"E-70C"
"E-82A"
6
Cause
Right level sen-
checked at the control board; have sensor checked and
sor open.
replace if necessary.
Both level sen-
sors open.
Slow heat
Have a certified service technician check the fryer for cor-
recovery.
rect voltage and have unit checked for loose or burnt
wires.
No heat.
Check power cord and have heat circuit checked.
Elements are up.
Lower elements back into the vat.
Programming
Turn switch to off, then back to on; if display shows any of
failure.
these error codes, have the controls re-initialized; if error
code persists, have the control board replaced.
Analog converter
Turn switch to off, then back to on; if "E-47" persists, have
chip or 12 volt
the PC board replaced.
supply failure.
Input system
Turn switch to off, then back to on; have control PC board
error.
replaced if "E-48" persists.
Temperature in-
Turn switch to off, then back to on; have control PC board
put error.
replaced if "E-54C" persists.
AIF PC board not
Turn switch to off, then back to on; if "E-60" persists, have
communicating
the connector between the PC boards checked; replace
with control PC
AIF PC board or control PC board if necessary.
board.
Communication
Loose connection. Refer to Service Manual.
error.
Replace control board.
Remove sensor.
Go to Level 1 Programmng –> Fryer Setup—> OQM
Enabled and select NO
Drain valve jump-
Have the jumper wire checked on the PC board at drain
er wire missing or
switch interlock position.
disconnected.
Selector valve
1 1 . . Enter HP info mode and set motor to continuous run.
not detected.
Jumper on pins
2 2 . . Ensure the yellow and blue lights flash. If the lights are
1&2 of 6 pin se-
flashing, then the motor is turning. If no, exit out of HP
lector valve wir-
info mode, and continue to step 3.
ing harness not
3 3 . . Disconnect selector valve motor
detected.
4 4 . . Enter HP info mode and set motor to continuous run.
Correction