Form inside of control area, squeeze in on tabs on back of switch and push
2 2 ) )
switch out the front of control area.
Label and remove wires from switch.
3 3 ) )
7 7 . . 8 8 . . 1 1 C C h h e e c c k k o o u u t t
Check across two sets of switch terminals for continuity. With switch in on
1 1 ) )
position, circuit should be closed. With switch in off position, circuit should be
open. If the switch is found to be defective, replace it by connecting the wires to
new switch (as labeled) and push switch into place.
7 7 . . 9 9 T T e e m m p p e e r r a a t t u u r r e e P P r r o o b b e e R R e e p p l l a a c c e e m m e e n n t t
The temperature probe relays the actual shortening temperature to the control. If it
becomes disabled, "E-6" will show in the display. Also, if temperature is out of
calibration more than 10°F or 10°C, the temperature probe should be replaced.
7 7 . . 9 9 . . 1 1 C C h h e e c c k k o o u u t t
Support control panel bottom with one hand, loosen retaining screw at panel
1 1 ) )
top, slide panel down slightly to clear screw, push panel bottom up, then swing
panel top out and down.
S S H H O O C C K K H H A A Z Z A A R R D D T T o o a a v v o o i i d d e e l l e e c c t t r r i i c c a a l l
s s h h o o c c k k , , m m o o v v e e t t h h e e p p o o w w e e r r s s w w i i t t c c h h t t o o o o f f f f a a n n d d
d d i i s s c c o o n n n n e e c c t t m m a a i i n n c c i i r r c c u u i i t t b b r r e e a a k k e e r r , , o o r r u u n n - -
p p l l u u g g c c a a r r d d a a t t w w a a l l l l r r e e c c e e p p t t a a c c l l e e . .