Henny Penny LVE-203 Technical Manual page 76

Open fryer reduced oil capacity
Hide thumbs Also See for LVE-203:
Table of Contents

Advertisement

Using a 1/4 inch or adjustable wrench, turn square stud shaft to operate valve
5 5 ) )
ball.
Assemble in reverse order.
6 6 ) )
Support control panel bottom with one hand, swing panel top up about 90
7 7 ) )
degrees, let panel slide down slightly to clear screw, push panel top up to
engage screw, then tighten screw.
7 7 . . 1 1 4 4 . . 2 2 R R e e p p l l a a c c e e m m e e n n t t
Each vat drain valve is opened and closed by an actuator. If oil won't drain or pump
back into a vat, the actuator may be faulty.
Support control panel bottom with one hand, loosen retaining screw at top, slide
1 1 ) )
panel down slightly to clear screw, push panel bottom up, then switch panel top
out and down.
64
S S H H O O C C K K H H A A Z Z A A R R D D T T o o a a v v o o i i d d e e l l e e c c t t r r i i c c a a l l
s s h h o o c c k k , , m m o o v v e e t t h h e e p p o o w w e e r r s s w w i i t t c c h h t t o o o o f f f f a a n n d d
d d i i s s c c o o n n n n e e c c t t m m a a i i n n c c i i r r c c u u i i t t b b r r e e a a k k e e r r , , o o r r u u n n - -
p p l l u u g g c c a a r r d d a a t t w w a a l l l l r r e e c c e e p p t t a a c c l l e e . .