T
ightening torques
To maintain the IP66 protection of the system and for optimal installation,
the following tightening torques must be used:
Tightening torques
Single core AC cable gland
PE cable gland M25
Multi core AC cable gland
Service cable gland
AC connection busbar
AC interface cables
PE interface cable
Protective earth point (int.)
Protective earth point (ext.)
Junction Screws
Side bracket screws
C
able gland clamping range
Cable gland clamping range
Single core AC cable gland
PE cable gland M25
Multi core AC cable gland
Service cable gland
M40
11
M63
56
M25
12
bolts
21
nut
25
nut
10
M40
11
M63
56
M25
12
- 26 -
3 - Characteristics
8.0 Nm
7.5 Nm
18 Nm
7.5 Nm
25 Nm
4.0 Nm
2.0 Nm
21 Nm
12 Nm
10 Nm
5 Nm
19...28mm
10...17mm
37...53mm
10...17mm