Replacement Of The Memory Board - ABB PVS-100-TL-B-SY2 Product Manual

Table of Contents

Advertisement

R
eplacement of the Memory board
45
X2
ZGN.V2Q15.2
S4
S5
2
8
1
7
J5
J7
J6
J1
1
2
3
4
Some inverter parts may be subject to voltages that could be hazardous for the operator.
Replacing the MEMORY board is carried out on the wiring box
may be necessary in case of Inverter log Statistic (e.g. power production)
lost after system shoutdown.
Procedure to replace the MEMORY board:
J2
X1
1. Before performing any work on the inverter, refer to "Inverter total de-
energization and safe access" chapter on this manual to know all the
necessary step to safely operate on the inverter.
2. Open the wiring box front cover
3. Extract the communication and control board
chapter "Communication and control board".
4. Remove the MEMORY board to be replaced
5. Install the new MEMORY board .
6. Close the wiring box front cover
7. Re-commission the inverter.
- 179 -
8 - Maintenance
.
07
as explained in the
28
.
45
.
07
and
02