a) Use the wire recommended by the manufacturer of the reader or keypad. If no wire is
recommended, use a minimum of 22 AWG wire with sufficient conductors that include
shield (drain).
b) If your reader interface uses standard Wiegand conventions, connect the wire properly
to the terminal block on the appropriate board node. Following is a typical, but not
universal, wiring guide. Refer to our Approved Wiegand and OSDP Reader List for
guidelines related to your specific reader or keypad.
c)
If your reader is OSDP using RS-485 wiring conventions, connect the wire properly to the
terminal block on the appropriate board node. Following is a typical, but not universal,
wiring guide. Refer to our Approved Wiegand and OSDP Reader List for guidelines
related to your specific reader or keypad.
© 2019 Brivo Systems LLC. All rights reserved.
NOTE: Refer to our Approved Wiegand and OSDP Reader List and connection
diagrams.
Connect the green reader wire to the DATA0 terminal. This is the standard
Data 0 circuit for Wiegand readers.
Connect the white reader wire to the DATA1 terminal. This is the standard
Data 1 circuit for Wiegand readers.
Connect the black reader wire to the GND terminal. This is the standard
Ground circuit for the reader.
Connect the blue reader wire to the BUZZ terminal. This is the standard
Buzzer circuit for the reader.
Connect the red reader wire to the 12VDC terminal. This provides +12VDC
to power the reader.
Connect the orange reader wire to the GRN LED terminal. This is the green
LED circuit.
Connect the brown reader wire to the RED LED terminal. This is the red
LED circuit.
Connect the wire to the RXD+ terminal. This is the standard RXD+ circuit
for OSDP readers using RS-485.
Connect the wire to the RXD- terminal. This is the standard RXD- circuit for
OSDP readers using RS-485.
Connect the wire to the GND terminal. This is the standard Ground circuit
for OSDP readers using RS-485.
Connect the wire to the 12VDC terminal. This provides +12VDC to power
OSDP readers using RS-485.
Brivo ACS6000 Installation Manual
P-MAN-PUB-ACS6000 Installation Manual
32