NOTE: To activate Full Duplex functionality on the ACS6000 MAIN BOARD for Door
1, put the FDX/HDX Door 1 switch in the FDX position. For Door 2, put the FDX/HDX
Door 2 switch into the FDX position.
To activate Half Duplex functionality on the ACS6000 MAIN BOARD for Door 1, put
the FDX/HDX Door 1 switch in the HDX position. For Door 2, put the FDX/HDX Door
2 switch in the HDX position.
Figure 17 - RS-485 Full Duplex/Half Duplex Switch Locations for Doors 1 and 2
NOTE: RS-485 bus requires termination. Door 1 RS-485 Term is the RS-485 Door 1
bus termination switch and Door 2 RS-485 Term is the RS-485 Door 2 bus
termination switch.
To enable RS-485 bus termination for Door 1, put the RS-485 termination switch in
the Enabled position. To enable RS-485 termination for Door 2, put the RS-485
termination switch in the Enabled position.
© 2019 Brivo Systems LLC. All rights reserved.
P-MAN-PUB-ACS6000 Installation Manual
30