Brivo Systems LLC. The information contained within this document or within the product itself is considered the exclusive property of Brivo Systems LLC. All information in this document or within the hardware and software product themselves is protected by the copyright and/or other intellectual property laws of the United States.
ACS6000 Control Panel at client sites. This version of the manual is also intended for IT personnel, who should use it in conjunction with the Brivo Panel Networking Admin Interface Guide. It may be used by dealers and their sales professionals to help them conduct pre-sales, and to provide client support during the installation process.
Brivo ACS6000 Installation Manual PRE-INSTALLATION PROCEDURES Before you begin installing the Brivo control panel, perform the following tasks to ensure a safe, speedy, and successful installation. Understand the function of the Brivo ACS6000 control panel. The ACS6000-E and ACS6000-A are four (4) reader control panels with multiple access points (up to four readers per chassis).
Page 8
Brivo ACS6000 Installation Manual 3. For Brivo Onair accounts, make sure the account has been created and the control panel is registered through Brivo Onair. If the control panel has not been registered by the dealer, the installer may either contact Brivo Technical Support for assistance or simply register the panel directly.
Page 9
Expansion Chassis Kit (B-ACS6000-EXP) or Large Expansion Chassis Kit (B- ACS6008-EXP). Each standard expansion chassis can hold up to two boards, including any combination of door and/or Input Output boards. Each large expansion chassis can hold up to four boards, including any combination of door and/or Input Output boards.
Page 10
An INPUT OUTPUT BOARD cannot be used to control a door; however, it can be used in any circumstance that uses contact closure to track change of status. d. Each large expansion chassis (ACS6008) may contain up to four boards, in any combination of DOOR BOARDs and/or INPUT OUTPUT BOARDs.
Make sure the chassis door can swing open freely to allow for access after the installation is complete. In tight spaces, the removable hinge design of the ACS6000/ACS6008 enclosures allow an installer to completely remove the chassis door and replace it just as easily upon completion of the installation.
Page 18
DO NOT POWER ELECTRONIC STRIKES AND LATCHES WITH THE BATTERY (OR OTHER POWER SOURCE) USED TO POWER THE CONTROL PANEL; DOING SO WILL CAUSE DAMAGE TO THE BRIVO CONTROL PANEL. USE ONLY A UL LISTED BURGLAR ALARM OR ACCESS CONTROL SYSTEM TO POWER ELECTRONIC STRIKES AND LATCHES.
If connecting two door/IO boards, use the first and second larger board connectors. In an ACS6008 enclosure, you have the option to connect a mainboard to three door/IO boards or to connect four door/IO boards together using the provided pre-assembled CAN Bus cable.
Page 35
DO NOT POWER ELECTRONIC STRIKES AND LATCHES WITH THE BATTERY (OR OTHER POWER SOURCE) USED TO POWER THE CONTROL PANEL; DOING SO WILL CAUSE DAMAGE TO THE BRIVO CONTROL PANEL. USE ONLY A UL LISTED BURGLAR ALARM OR ACCESS CONTROL SYSTEM TO POWER ELECTRONIC STRIKES AND LATCHES.
1. Plug the transformer into a 120VAC outlet. NOTE: Firmware Upgrade at First Time Connect When first registered and connected to the Brivo Onair cloud service, your ACS300 will automatically download and install the latest firmware. This process may take several minutes, so do not disconnect or cut power to your ACS300 during this process.