b) 1 lock and key set
c)
An identify label to be adhered to the inside of the door
d) Battery and PSU cardboard box
Plan your installation.
1. Determine the size of your control panel.
a.
In addition to the control chassis, which contains the MAIN BOARD, there may be up to
seven expansion chassis.
b. The control chassis contains the MAIN BOARD, which also serves as a 2-door board, and
may also contain either a DOOR BOARD or an INPUT OUTPUT BOARD.
c.
Each standard expansion chassis (ACS6000) may contain up to two boards, in any
combination of DOOR BOARDs and/or INPUT OUTPUT BOARDs.
d. Each large expansion chassis (ACS6008) may contain up to four boards, in any
combination of DOOR BOARDs and/or INPUT OUTPUT BOARDs.
© 2019 Brivo Systems LLC. All rights reserved.
1 hinge pair short
1 hinge pair long
1 power supply board
1 pair of battery wires
1 AC transformer
1 7Ah lead-acid battery (x2 for ACS6008)
Each DOOR BOARD has two terminal nodes, each of which contains a complete set
of terminals for controlling a door. This means that each DOOR BOARD can be used
to control two doors.
The same inputs and outputs that drive a door can also be used for other devices. In
other words, DOOR BOARDs do not need to be used to control doors.
WARNING: Door Wiring
If a node is to be used for a door, do not connect any other device to the following
terminal blocks: REX & DOOR, DOOR LOCK RELAY, and READER.
An INPUT OUTPUT BOARD cannot be used to control a door; however, it can be
used in any circumstance that uses contact closure to track change of status.
Each DOOR BOARD has two terminal nodes, each of which contains a complete set
of terminals for controlling a door. This means that each DOOR BOARD can be used
to control two doors.
The same inputs and outputs that drive a door can also be used for other devices. In
other words, DOOR BOARDs do not need to be used to control doors.
WARNING: Door Wiring
If a node is to be used for a door, do not connect any other device to the following
terminal blocks: REX & DOOR, DOOR LOCK RELAY, and READER.
Brivo ACS6000 Installation Manual
P-MAN-PUB-ACS6000 Installation Manual
10