Mitsubishi Electric FR-F820-04750 Instruction Manual page 302

Hide thumbs Also See for FR-F820-04750:
Table of Contents

Advertisement

(D) Operation command and frequency command
JOG operation in the External operation
● Operation can be started and stopped by the start signals (STF and STR signals) when the Jog
operation selection (JOG) signal is ON. (For the operation method, refer to page 4-30.)
● In the initial setting, the JOG signal is assigned to the terminal JOG.
Fig. 5-41:
JOG operation in PU
When the operation panel or the parameter unit is in the JOG operation mode, the motor jogs only
while the start button is pressed.
(For the operation method, refer to page 4-31.)
NOTES
The reference frequency of the acceleration/deceleration time differs according to the Pr. 29
"Acceleration/deceleration pattern selection" setting. (Refer to page 5-104.)
The Pr. 15 setting should be equal to or higher than the Pr. 13 "Starting frequency" setting.
The JOG signal can be assigned to an input terminal by setting Pr. 178 to Pr. 189 (input terminal
function selection). Changing the terminal assignment may affect other functions. Set parameters
after confirming the function of each terminal.
During JOG operation, the second acceleration/deceleration cannot be selected with the RT sig-
nal. (Other second functions are enabled. (Refer to page 5-285.))
When Pr. 79 "Operation mode selection" = "4", JOG operation is started by one push of FWD/REV
key on the operation panel (FR-DU08) and stopped by STOP/RESET key.
This function is invalid when Pr. 79 = "3".
Parameters referred to
Pr. 13
Pr. 20
Pr. 21
Pr. 29
Pr. 79
Pr. 178 to Pr. 182
5 - 140
Output
frequency (Hz)
Pr. 20
Pr. 15
setting range
JOG signal
Forward rotation STF
Reverse rotation STR
Jog operation signal timing chart
Starting frequency
Acceleration/deceleration reference frequency
Acceleration/deceleration time increments
Acceleration/deceleration pattern selection
Operation mode selection
(input terminal function selection)
Forward
rotation
Reverse
rotation
Pr. 16
ON
ON
ON
Parameters
Time
=>
page 5-112
=>
page 5-99
=>
page 5-99
=>
page 5-104
=>
page 5-116
=>
page 5-279
I002576E