Mitsubishi Electric FR-F820-04750 Instruction Manual page 191

Hide thumbs Also See for FR-F820-04750:
Table of Contents

Advertisement

Parameters
(M) Monitor display and monitor output signal
Parameters regarding the inverter's operating status.
These parameters are used to set the monitors and out-
put signals.
Pr.
Pr.
Name
group
M000
37
Speed display
M001
505
Speed setting reference
M002
144
Speed setting switchover
M020
170
Watt-hour meter clear
Energization time carrying-over
M021
563
times
M022
268
Monitor decimal digits selection
Cumulative power monitor digit
M023
891
shifted times
M030
171
Operation hour meter clear
M031
564
Operating time carrying-over times
M040
55
Frequency monitoring reference
M041
56
Current monitoring reference
M042
866
Torque monitoring reference
M043
241
Analog input display unit switchover
M044
290
Monitor negative output selection
M045
1018
Monitor with sign selection
M050
1106
Torque monitor filter
M051
1107
Running speed monitor filter
M052
1108
Excitation current monitor filter
Control circuit temperature signal
M060
663
output level
Operation panel main monitor
M100
52
selection
M101
774
Operation panel monitor selection 1
M102
775
Operation panel monitor selection 2
M103
776
Operation panel monitor selection 3
Operation panel setting dial push
M104
992
monitor selection
M200
892
Load factor
Energy saving monitor reference
M201
893
(motor capacity)
Control selection during commercial
M202
894
power-supply operation
M203
895
Power saving rate reference value
M204
896
Power unit cost
M205
897
Power saving monitor average time
Power saving cumulative monitor
M206
898
clear
Operation time rate (estimated
M207
899
value)
M300
54
FM/CA terminal function selection
M301
158
AM terminal function selection
Tab. 5-10:
Monitor display and monitor output
signal (1)
FR-F800
Pr.
Pr.
group
C0
M310
(900)
C1
M320
Refer to
(901)
page
M321
867
5-191
C8
M330
5-191
(930)
5-191
C9
M331
(930)
5-193
C10
M332
(931)
5-193
C11
M333
5-193
(931)
5-193,
M334
869
5-219
M400
190
5-193
M401
191
M402
192
5-193
M403
193
5-206
M404
194
5-206
M405
195
5-206
M406
196
5-260
M430
157
5-193,
5-206
M431
289
5-193
M433
166
5-193
M440
870
5-193
M441
41
5-193
M442
42
5-248
M443
43
5-193
M444
50
M460
150
5-193
5-193
M461
151
5-193
M462
152
M463
153
5-193
M464
167
5-219
M470
864
5-219
M500
495
5-219
M501
496
M502
497
5-219
M510
76
5-219
5-219
M520
799
5-219
M530
655
M531
656
5-219
M532
657
5-206
M533
658
5-206
M534
659
Tab. 5-10:
Name
FM/CA terminal calibration
AM terminal calibration
AM output filter
Current output bias signal
Current output bias current
Current output gain signal
Current output gain current
Current output filter
RUN terminal function selection
SU terminal function selection
IPF terminal function selection
OL terminal function selection
FU terminal function selection
ABC1 terminal function selection
ABC2 terminal function selection
OL signal output timer
Inverter output terminal filter
Output current detection signal
retention time
Speed detection hysteresis
Up-to-frequency sensitivity
Output frequency detection
Output frequency detection for
reverse rotation
Second output frequency detection
Output current detection level
Output current detection signal
delay time
Zero current detection level
Zero current detection time
Output current detection operation
selection
Torque detection
Remote output selection
Remote output data 1
Remote output data 2
Fault code output selection
Pulse increment setting for output
power
Analog remote output selection
Analog remote output 1
Analog remote output 2
Analog remote output 3
Analog remote output 4
Monitor display and monitor output
signal (2)
Parameter List
Refer to
page
5-213
5-213
5-213
5-213
5-213
5-213
5-213
5-213
5-226
5-226
5-226
5-226
5-226
5-226
5-226
5-175
5-226
5-238
5-234
5-234
5-234
5-234
5-234
5-238
5-238
5-238
5-238
5-238
5-240
5-241
5-241
5-241
5-246
5-247
5-243
5-243
5-243
5-243
5-243
5 - 29