Mitsubishi Electric FR-F820-04750 Instruction Manual page 211

Hide thumbs Also See for FR-F820-04750:
Table of Contents

Advertisement

Parameters
Pr.
Name
Pr. 998
Overspeed detection
374
level
% setting reference
390
frequency
505 Speed setting reference
Current average value
557
monitor signal output
reference current
Speed detection
870
hysteresis
Regeneration avoidance
885
compensation
frequency limit value
Energy saving monitor
893
reference (motor
capacity)
C14
Terminal 1 gain
(918)
frequency (speed)
⎯: Not changed
Tab. 5-21:
PM parameter initialization list (2)
Initial value for the FR-F820-02330(55K) or lower and FR-F840-01160(55K) or lower.
Initial value for the FR-F820-03160(75K) or higher and FR-F840-01800(75K) and higher.
Setting Pr. 71 "Applied motor" = "213, 214, 243, 244, 8093, 8094, 9093, or 9094" does not change
the Pr. 71 setting.
When a value other than "9999" is set, the set value is not changed.
110% for SLD, 120% for LD (refer to Pr. 570 "Multiple rating setting" page 5-68).
The Pr. 702 "Maximum motor frequency" is used as the maximum motor frequency (rotations per
minute). When Pr. 702 = "9999 (initial value)", the Pr. 84 "Rated motor frequency" is used as the
maximum motor frequency (rotations per minute).
The setting value is converted from frequency to rotations per minute. (The value after the conversion
differs according to the number of motor poles.)
NOTE
If PM parameter initialization is performed in rotations per minute (Pr. 998 = "12, 14, 8009, or
9009"), the parameters not listed in the table and the monitored items are also set and displayed
in rotations per minute.
FR-F800
Induction motor
(rotations per minute)
0
(initial value)
12
FM
CA
Overspeed detection
9999
level, rotations per
minute
Rated motor
60 Hz
50 Hz
rotations per minute
Rated motor
60 Hz
50 Hz
frequency
Rated motor
Rated inverter
current
current
(Refer to page 8-4.)
Speed detection
0 Hz
hysteresis rotations
per minute
Minimum rotations
6 Hz
per minute
Rated inverter
capacity
Rated motor
60 Hz
50 Hz
rotations per minute
Setting
PM motor
PM motor (frequency)
8009
14
112
9009
Maximum
motor
Overspeed detection
frequency
level, frequency
+10 Hz
Rated motor
Pr. 84
frequency
Rated motor
Pr. 84
frequency
Rated motor
Pr. 859
current
(Refer to page 8-4.)
Speed detection
0.5 Hz
hysteresis frequency
Pr. 84 ×
Minimum frequency
10%
Motor capacity (Pr. 80)
Rated motor
Pr. 84
frequency
Control method
Setting increments
12,14,
8109
114
8009,
9109
9009
Maximum
motor
1 r/min
frequency
+10 Hz
Pr. 84
1 r/min
Pr. 84
0.01 Hz
0.01 A
Pr. 859
0.1 A
0.5 Hz
1 r/min
Pr. 84 ×
1 r/min
10%
0.01 kW
0.1 kW
Pr. 84
1 r/min
0,
112,114,
8109,
9109
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
5 - 49