(4) 1 pulse input magnification setting registers for manual pulse generators
(D1016 to D1023)........................................... Data from the SCPU to the PCPU
(a) This register is used to set the magnification (from 1 to 100) per pulse for
the number of input pulses from a manual pulse generator in manual pulse
generator operation.
<A172SHCPUN>
1-pulse Input Magnification
Setting Register
<A171SHCPUN>
1-pulse Input Magnification
Setting Register
(b) For details on manual pulse generator operation, see Section 7.20.
search engine
Corresponding
Axis No.
D1016
Axis 1
D1017
Axis 2
D1018
Axis 3
D1019
Axis 4
D1020
Axis 5
D1021
Axis 6
D1022
Axis 7
D1023
Axis 8
Corresponding
Axis No.
D1016
Axis 1
D1017
Axis 2
D1018
Axis 3
D1019
Axis 4
3 − 40
Setting
Range
1 to 100
Setting
Range
1 to 100