5. SEQUENCE PROGRAMS AND SFC PROGRAMS
[Error Details]
[Program example]
M9039
0
M9074
2
M0100
M9074
4
M0
11
M1
M9074
13
CIRCUIT END
Downloaded from
ManualsNet.com
Example
Make the following setting to designate the number of the servo program to be
started with the data stored in data register D50:
• Designation with a word device
2) An index register (Z, V) can be used for index designation of the indirectly
set word device.
• For details on index registers (Z, V), see the ACPU Programming
Manual (Fundamentals) (IB-66249).
In the following cases, an operation error occurs and the SVST instruction is not
executed.
• When the setting for (D) is for 5 or more axes (A171SHCPUN).
• When the setting for (D) is for 8 or more axes (A172SHCPUN).
• When the axis number given in any digit of (D) is a number other than J1 to J4
(A171SHCPUN).
• When the axis number given in any digit of (D) is a number other than J1 to J8
(A172SHCPUN).
• When the same axis number is set twice in (D).
• When the setting for n is outside the applicable range.
M2009 M9076
M2001 M2002 M2003 M2004
Start accept flags
search engine
SVST J1J2J3
PLC READY flag turned ON
M2000
All axes servo start command turned ON
M2042
PLS
M0
SET
M1
K
SVST
J1J2J3J4
50
Execution request for servo program No.50.
RST
M1
On completion of the request for execution
of servo program No.50, M1 is turned OFF.
5 − 7
D50
When X100 comes ON, the start
command flag (M1) for servo program
No.50 comes ON.