Table 3-16 : Electrical specifications for the output circuits
Item
Type
No. of output points
Insulation method
Rated load voltage
Rated load voltage range
Max. load current
Leakage current at OFF
Max. voltage drop at ON
OFF-ON
Response time
ON-OFF
Fuse rating
Common method
External wire connection
method
Voltage
External power
supply
Current
CAUTION
Specification
Transistor output
32
Photo-coupler insulation
12VDC/24VDC
10.2 to 30VDC(peak voltage 30VDC)
0.1A/point (100%)
0.1mA or less
0.9VDC(TYP.)
2ms or less
(hardware response time)
2ms or less
(Resistance load) (hardware response time)
Fuse 3.2A (one per common) Replacement not possible
8 points per common (common terminal: 8 points)
Connector
12VDC/24VDC(10.2 to 30VDC)
60mA (TYP. 24VDC per common) (base drive current)
The output circuit protective fuses prevent failure in case of load short-circuit and
improper connections. Please do not connect loads that cause the current to exceed
the maximum rated current. If the maximum rated current is exceeded, the internal
transistors may be damaged.
Internal circuit
<Sink type>
(24/12V)
Fuse
<Source type>
Fuse (24/12V)
Outline
3Controller
Outline
(0V)
(0V)
Options 3-71