Lenovo ThinkSystem DA240 Reference page 45

Enclosure and compute node
Table of Contents

Advertisement

SNMP Trap ID: 560922652
User Action:
1. Reset the BMC on indicated compute node.
2. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
3. If the event persists, replace the indicated compute node. (Service technician only)
4. If the event persists, please consult with technical service.
• 216F001D: Node 2 BMC: Slot Or Connector, Fault Status asserted was asserted.
The BMC on indicated compute node unable to response to the initial request in 2 minutes after the
compute node inserted.
Severity: Error
Alert Category: Node - Node event
SNMP Trap ID: 560922653
User Action:
1. Reset the BMC on indicated compute node.
2. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
3. If the event persists, replace the indicated compute node. (Service technician only)
4. If the event persists, please consult with technical service.
• 216F001E: Node 3 BMC: Slot Or Connector, Fault Status asserted was asserted.
The BMC on indicated compute node unable to response to the initial request in 2 minutes after the
compute node inserted.
Severity: Error
Alert Category: Node - Node event
SNMP Trap ID: 560922654
User Action:
1. Reset the BMC on indicated compute node.
2. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
3. If the event persists, replace the indicated compute node. (Service technician only)
4. If the event persists, please consult with technical service.
• 216F001F: Node 4 BMC: Slot Or Connector, Fault Status asserted was asserted.
The BMC on indicated compute node unable to response to the initial request in 2 minutes after the
compute node inserted.
Severity: Error
Alert Category: Node - Node event
SNMP Trap ID: 560922655
User Action:
1. Reset the BMC on indicated compute node.
2. If the event persists, ensure the indicated compute node is completely power off, and then reseat it.
(Service technician only)
3. If the event persists, replace the indicated compute node. (Service technician only)
4. If the event persists, please consult with technical service.
.
41
Chapter 2
SMM2 events

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem sd630 v27d1j7d1k

Table of Contents