Lenovo ThinkSystem DA240 Reference page 134

Enclosure and compute node
Table of Contents

Advertisement

Please check the event log in System Management Module 2 (SMM2) Web GUI to identify the power
supply unit failure.
• FQXSPPW0003G: Failure predicted on [PowerSupplyElementName].
This message is for the use case when an implementation has detected a Power Supply failure is
predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID: 164
CIM Prefix: PLAT CIM ID: 0088
User Action:
Please check the event log in System Management Module 2 (SMM2) Web GUI to identify the power
supply unit failure.
• FQXSPPW0005I: [PowerSupplyElementName] is operating in an Input State that is out of range.
This message is for the use case when an implementation has detected a Power Supply that has input out
of range.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0098
User Action:
Information only; no action is required
• FQXSPPW0006I: [PowerSupplyElementName] has lost input.
This message is for the use case when an implementation has detected a Power Supply that has input
that has been lost.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0100
User Action:
Make sure the power cords are connected correctly.
• FQXSPPW0007L: [PowerSupplyElementName] has a Configuration Mismatch.
This message is for the use case when an implementation has detected a Power Supply with a
Configuration Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4