Lenovo ThinkSystem DA240 Reference page 20

Enclosure and compute node
Table of Contents

Advertisement

2. If the event persists, ensure all populated compute nodes are completely power off, then reseat
SMM2 module. (Service technician only)
3. If the event persists, ensure all populated compute nodes are completely power off, then replace the
SMM2 module. (Service technician only)
4. If the event persists, please consult with technical service.
• 0201070C: SMM2 Brd 5V: Voltage sensor, warning event was asserted, reading value %V
(Threshold %V)
Asserted when voltage sensed on 5V power rail is higher than upper non-critical threshold.
Severity: Information
Alert Category: System - SMM2 system event
SNMP Trap ID: 33621772
User Action:
1. Virtual reset SMM2 via Web GUI or IPMI command.
2. If the event persists, ensure all populated compute nodes are completely power off, then reseat
SMM2 module. (Service technician only)
3. If the event persists, ensure all populated compute nodes are completely power off, then replace the
SMM2 module. (Service technician only)
4. If the event persists, please consult with technical service.
• 0201070D: SMM2 Brd 12V: Voltage sensor, warning event was asserted, reading value %V
(Threshold %V)
Asserted when voltage sensed on 12V power rail is higher than upper non-critical threshold.
Severity: Information
Alert Category: System - SMM2 system event
SNMP Trap ID: 33621773
User Action:
1. Virtual reset SMM2 via Web GUI or IPMI command.
2. If the event persists, ensure all populated compute nodes are completely power off, then reseat
SMM2 module. (Service technician only)
3. If the event persists, ensure all populated compute nodes are completely power off, then replace the
SMM2 module. (Service technician only)
4. If the event persists, please consult with technical service.
• 02010908: SMM2 Brd 1.15V: Voltage sensor, critical event was asserted, reading value %V
(Threshold %V)
Asserted when voltage sensed on 1.15V power rail is higher than high critical threshold.
Severity: Error
Alert Category: System - SMM2 system event
SNMP Trap ID: 33622280
User Action:
1. Virtual reset SMM2 via Web GUI or IPMI command.
2. If the event persists, ensure all populated compute nodes are completely power off, then reseat
SMM2 module. (Service technician only)
3. If the event persists, ensure all populated compute nodes are completely power off, then replace the
SMM2 module. (Service technician only)
4. If the event persists, please consult with technical service.
16
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem sd630 v27d1j7d1k

Table of Contents