Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0162
User Action:
Information only; no action is required
• FQXSPSD0001L: The [StorageVolumeElementName] has been disabled due to a detected fault.
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0164
User Action:
Complete the following steps:
1. Check the Support Portal(http://support.lenovo.com/) for service bulletins and TECH tips and
firmware update related to your drive.
2. Check for any other RAID-related error.
3. Replace the drive.
• FQXSPSD0002G: Failure Predicted on [StorageVolumeElementName] for array
[ComputerSystemElementName].
This message is for the use case when an implementation has detected an Array Failure is Predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: System - Predicted Failure
SNMP Trap ID: 27
CIM Prefix: PLAT CIM ID: 0168
User Action:
Replace drive 0 at the next maintenance period.
• FQXSPSD0002L: Drive [arg1] in the enclosure/chassis(MTM-SN: [arg2]) has been disabled due to a
detected fault.
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0164
User Action:
Complete the following steps:
138
ThinkSystem DA240 Enclosure and ThinkSystem SD630 V2 Compute Node Messages and Codes Reference