Table 1. Events organized by severity (continued)
Message String
Event ID
02010909
SMM2 Brd 1.2V: Voltage sensor, critical event was asserted, reading
value %V (Threshold %V)
0201090A
SMM2 Brd 2.5V: Voltage sensor, critical event was asserted, reading
value %V (Threshold %V)
0201090B
SMM2 Brd 3.3V: Voltage sensor, critical event was asserted, reading
value %V (Threshold %V)
0201090C
SMM2 Brd 5V: Voltage sensor, critical event was asserted, reading
value %V (Threshold %V)
0201090D
SMM2 Brd 12V: Voltage sensor, critical event was asserted, reading
value %V (Threshold %V)
04010279
Fan 1 Tach A: Fan sensor, critical event was asserted, reading value
%RPM (Threshold %RPM)
0401027A
Fan 1 Tach B: Fan sensor, critical event was asserted, reading value
%RPM (Threshold %RPM)
0401027B
Fan 2 Tach A: Fan sensor, critical event was asserted, reading value
%RPM (Threshold %RPM)
0401027C
Fan 2 Tach B: Fan sensor, critical event was asserted, reading value
%RPM (Threshold %RPM)
0401027D
Fan 3 Tach A: Fan sensor, critical event was asserted, reading value
%RPM (Threshold %RPM)
0401027E
Fan 3 Tach B: Fan sensor, critical event was asserted, reading value
%RPM (Threshold %RPM)
04080076
Fan 1: Fan sensor, Device Removed / Device Absent was asserted.
04080077
Fan 2: Fan sensor, Device Removed / Device Absent was asserted.
04080078
Fan 3: Fan sensor, Device Removed / Device Absent was asserted.
08080080
PSU 1: Power Supply, Device Removed / Device Absent was
asserted.
08080081
PSU 2: Power Supply, Device Removed / Device Absent was
asserted.
086F0180
PSU 1: Power Supply, Power Supply Failure detected was asserted.
086F0181
PSU 2: Power Supply, Power Supply Failure detected was asserted.
086F01A4
PSU 1 Vin UV: Power Supply, Power Supply Failure detected was
asserted.
086F01A5
PSU 2 Vin UV: Power Supply, Power Supply Failure detected was
asserted.
086F01AD
PSU 1 Iout OC: Power Supply, Power Supply Failure detected was
asserted.
086F01AE
PSU 2 Iout OC: Power Supply, Power Supply Failure detected was
asserted.
086F01B6
PSU 1 Vout OV: Power Supply, Power Supply Failure detected was
asserted.
086F01B7
PSU 2 Vout OV: Power Supply, Power Supply Failure detected was
asserted.
Severity
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
.
9
Chapter 2
SMM2 events

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem sd630 v27d1j7d1k

Table of Contents